Honeywell AWM3100V Gas Mass Flow Sensor

The Honeywell AWM3100V is an amplified microbridge mass gas flow sensor designed for ultra-low flow measurement. Featuring a ±200 SCCM range, a fast 1 ms response time, and a pre-calibrated 5V ratiometric analog output, it provides stable, high-precision detection for gas chromatography and medical respirators.

分类:
The Honeywell AWM3100V is a fully signal-conditioned microbridge thermal mass gas flow sensor from the AWM3000 Series. Utilizing specialized silicon MEMS technology, it ensures accurate repeatability, low pressure drop, and dependable ratiometric output for non-corrosive gases.
Key Features
  • Sensor Type: Amplified / Signal Conditioned Mass Flow Sensor
  • Flow Range: ±200 SCCM (Standard Cubic Centimeters per Minute)
  • Output Signal: 5.00 Vdc analog voltage at full scale
  • Response Time: 1.0 ms typical / 3.0 ms maximum
  • Port Configuration: 5.08 mm (0.2 inch) male plastic ports
  • Operating Voltage: 8.0 Vdc to 15.0 Vdc (10.0 Vdc recommended)
  • Power Consumption: 50 mW low power requirement
  • Operating Temperature: -25 to 85 degrees Celsius
Applications
  • Medical Equipment: Oxygen concentrators, sleep apnea monitors, anesthesia devices, and ventilators.
  • Industrial Applications: Gas chromatography, leak detection systems, environmental analysis, and process gas control.